- Welded steel lateral bracing frames
- Available on the shelf to suit standard-size ceiling heights
- For use in timber and steel frame construction
- No leadtimes
- Allows for maximum open-plan living with minimum walls
- Custom sizes available upon request
ENGINEERED LATERAL WALL BRACING SYSTEM
Installation Instructions
• Mark hole positions – Minimum 60 or 75mm from edge and 100mm from the returning edge as per the Diagram.
• Drill 2x Ø22mm hole to 240mm minimum depth.
• Remove dust - Chemset M20 Grade 8.8 threaded rod and allow to set before tightening. (Refer Ramset Reo502 PLUS installation guide).
• In order to Achieve Compliance, the Installer shall refer to the AJ Brace capacity table to determine the edge clearance required.
• Fix the top of the AJ Brace to the top plate in accordance with good building Practices unless specified otherwise in the site-specific Engineering.
Click the download button below to download installation instructions